Microlife MIC BPB2 Basic Blood Pressure Monitor 1.00 Piece
Microlife MIC BPB2 Basic Blood Pressure Monitor 1.00 Piece
In stock
Free delivery on orders of €70 or more in NL & BE
Order before 9.00 pm, delivered tomorrow
Couldn't load pickup availability
Returns
Returns
When you buy directly from us, we want you to be 100% satisfied with your shopping experience. We hope you love everything you receive from us, but if you’re not 100% satisfied, you can return or exchange any item within 30 days of your purchase. Please contact a member of our customer service team if your order isn’t to your liking or doesn’t meet your needs. We want to resolve this for you as quickly and easily as possible.
Step 1: Fill in the return details on the back of your order form. Can’t find your order form? Then download a copy of the returns form. Would you like to exchange the product for another one? Please let us know within 30 days of purchase.
Step 2: Return the order yourself via USPS, FedEx or another trackable delivery method. We recommend that you insure your parcel.
Please note that it may take up to 14 days for us to receive and process your return. The original postage and administration charges will not be refunded. We will credit or refund the cost of the returned items and any taxes charged, minus the original postage costs. Please contact customer services for further information about our returns policy. Any changes to your credit card statement should appear within two billing cycles.
Delivery
Delivery
Ordered before 9.00 pm? Your order will be delivered the next working day.
Free delivery on orders of €70 or more in the Netherlands. For orders outside the Netherlands, delivery charges will be shown at checkout.
Quality & safety
Quality & safety
Carefully selected products: We select our products with care and work with reliable brands and suppliers.
Quality is our top priority: All products are supplied in accordance with the applicable quality and safety standards.
Secure payment
Secure payment
Secure & reliable payment
Pay easily and securely using the available payment methods. Your payment details are processed securely and protected.
Available payment methods: iDEAL, Visa, Mastercard, American Express, Postepay
Microlife MIC BPB3 Basic blood pressure monitor
Operating conditions: 10 - 40 °C / 50 - 104 °F
15-90 % maximum relative humidity
Weight: 277 g (including batteries)
Dimensions: 131 x 90 x 60.5 mm
Cuff dimensions: from 17 - 52 cm
Measurement procedure: oscillometric, according to the Korotkoff
method: Phase I systolic Phase V diastolic
Measurement range: SYS: 60 - 255 mmHg
DIA: 40 - 200 mmHg
Pulse: 40 - 199 beats per minute
Cuff pressure display range: 0 - 299 mmHg
Resolution: 1 mmHg
Static accuracy: within ± 3 mmHg
Heart rate accuracy: ±5 % of displayed value
Power source: 4 x 1.5V alkaline batteries; type AA
AC adapter DC 6V, 600 mA (optional)
Battery life: approximately 920 measurements (with new
batteries)
IP Class: IP 20
Reference to standards:
IEC 80601-2-30; IEC 60601-1;
IEC 60601-1-2 (EMC); IEC 60601-1-11
Expected lifespan:
Device: 5 years or 10000 measurements, whichever comes first.
Accessories: 2 years or 5000 measurements, whichever comes first
This device complies with the standards of Medical Devices Directive 93/42/EEC.
Technical modifications reserved.
Usage
Blood pressure measurement.
Instructions for use
Inserting the batteriesAfter unpacking the device, first insert the batteries.The battery compartment 7 is located at the bottom ofthe device. Insert the batteries (4 x 1.5 V, size AA), paying attentionto the indicated polarity.Setting date and time1. After the batteries are inserted, the year flashes on the screen. You can set the year by pressing the M button 3. To confirm and then set the month, press the time button 4.2. Now you can set the month with the M button. Press the time button to confirm and then set the day.3. Follow the instructions above to set day, hour and minutes.4. Once you have set the minutes and press the time button, the date and time are set and the time is displayed.5. If you want to change the date and time, press and hold the time button for approx. 3 seconds until the year starts flashing. Now you can enter new values as described above.Select the correct cuffMicrolife has cuffs in different sizes. Select the cuff size that corresponds to the circumference of your upper arm (the measured circumference around the middle of the upper arm).Contact your Microlife importer if the included cuff 8 does not fit.Attach the cuff to the device using the cuff connector 9, pushing the connector 5 as far as possible into the device.Cuff size for upper arm circumferenceS 17 - 22 cmM 22 - 32 cmM - L 22 - 42 cmL 32 - 42 cmL - XL 32 - 52 cmPre-formed cuffs are optionally available.Only use Microlife cuffs!Step-by-step plan for a reliable blood pressure measurementAvoid activity, eating or smoking just before a measurement.Sit on a chair with a backrest and relax for 5 minutes.Keep your feet side by side on the floor and do not cross your legs.Always measure on the same arm (normally left). It is recommended that doctors measure both arms during a patient's first visit to determine the arm to be measured. The arm with the higher blood pressure should be measured.Remove clothing covering the upper arm, sleeves should not be rolled up to avoid constriction.Always ensure that the correct cuff size is used (arm circumference marking is indicated on the cuff).Attach the cuff around the arm, but not too tightly.Ensure the cuff is placed 1-2 cm above your elbow.The artery mark on the cuff (approx. 3 cm long bar) should be placed on the artery of the arm (inner side).Support your arm so it is relaxed.Ensure the cuff is at the same height as your heart.Measuring blood pressure1. Press the ON/OFF button 1 to start the measurement.2. The cuff will now automatically inflate. Relax,do not move and do not tense your arm muscles until the measurement result is shown. Breathe normally and do not talk.3. If the cuff is correctly placed, the Cuff Check Indicator AR symbol appears on the screen. If the symbolCuff Position Check AR-A appears, the cuff ismoderately placed but a correct blood pressure measurement can still be performed.4. When the correct pressure is reached, pumping stops and the pressure slowly decreases. If the desired pressure was not reached, the device will automatically pump more air into the cuff.5. During the measurement, the heart rate symbol AQ flashes on the screen.6. The result, including the systolic AK and diastolic AL blood pressure and the heart rate AM, is displayed.Also consult this manual for an explanation of other displays.7. When the measurement is complete, remove the cuff.8. Turn off the device. (The monitor will automatically turn off after approx. 1 min.).You can stop the measurement at any time by pressing the ON/OFF button or opening the cuff (e.g. if you feel uncomfortable or experience unpleasant pressure).This meter has been specially tested for use during pregnancy and pre-eclampsia. If you record unusually high readings, you should repeat the measurement at a later time (e.g. 1 hour). If the reading is still too high, consult your doctor or gynaecologist.Manually setting inflationIn case of high systolic blood pressure (e.g. above 135 mmHg), it may be beneficial to set the pressure manually. Press the ON/OFF button when the blood pressure monitor is inflated to approximately 30mmHg. Keep the button pressed until the pressure is approximately 40 mmHg higher than the expected systolic value and then release the button.Performing a measurement without saving itOnce the measurement is completed and the result is displayed, hold down the ON/OFF button 1 until the «M» AP appears in the display. Then press the time button 4 and the measurement will be deleted and not saved.When the measurement is successfully deleted, «CL» appears in the display.How do I measure my blood pressure?The triangular symbol, on the left side of the display AO, applies to the classification of home blood pressure readings in adults in accordance with international guidelines (ESH, ESC,JSH). The blood pressure value: Optimal (white), elevated (shaded grey) or too high (black). Values in mmHg.Range Systolic Diastolic Advice1. blood pressure too high >/= 135 >/= 85 Seek medical advice2. blood pressure elevated 130 - 134 80 - 84 Self-monitoring3. blood pressure normal <130 <80 Self-monitoringThe evaluation of the values is in accordance with the table. For example:a blood pressure value of 140/80 mmHg or a valueof 130/90 mmHg shows «blood pressure too high».Appearance of the irregular heartbeat (IHB) symbolThis symbol BT indicates that an irregular heartbeat has beendetected. In this case, the measured blood pressure may deviate fromyour actual blood pressure values. It is recommended to repeat themeasurement.Information for the physician in case of repeatedappearance of the IHB symbolThis device is an oscillometric blood pressure monitor that also measures thepulse during blood pressure measurement and indicates when the heart rate is irregular.Memory storageThis device stores the last 30 measurement values.Viewing stored valuesPress the M button 3 when the device is switched off. The display first shows «M» AP and «A», which stands for the average of all stored values.Pressing the M button again shows the previous value. By pressing the M button again, you can scroll through the measurement results.Clear all valuesIf you are sure you want to permanently delete all stored values, press and hold the M button (first switch off the device) until «CL ALL» appears and then release the button. To permanently clear the memory, press the time button while «CL ALL» is flashing. Individual measurements cannot be deleted.Cancel deletion: press the ON/OFF button 1 while «CL ALL» is flashing.Battery indicator and battery replacementBatteries almost emptyWhen the batteries are approximately ¾ used, the battery symbol AN will flash as soon as the device is switched on(partially charged battery is displayed). Although thedevice will continue to measure reliably, you should replace the batteriessoon.Batteries empty – replacementWhen the batteries are empty, the battery symbol AN will flash as soon as the device is switched on (empty battery displayed). You cannot continue measuring and must replace the batteries.1. Open the battery compartment 7 on the back of the device.2. Replace the batteries – check the correct polarity asshown by the symbols in the compartment.3. To set the date and time, follow the procedure asdescribed in Section «First use of the device».Which batteries and which method?Use 4 new, long-life 1.5V, type AA alkaline batteries.Do not use batteries whose expiry datehas passed.Remove the batteries if the device is not going to beused for a longer period of time.Use of rechargeable batteriesYou can also use rechargeable batteries for this device.Please only use «NiMH» rechargeable batteries!The batteries must be removed and recharged ifthe battery symbol (empty battery) appears! They should notremain in the device, as they can be damaged(complete discharge due to minimal useof the device, even when it is off).Always remove rechargeable batteries if you do not planto use the device for a week or more!The batteries CANNOT be recharged in the blood pressure monitor! Recharge these batteries in an externalcharger and adhere to the information regardingcharging, maintenance and durability!Use of an AC adapterYou can use this device with the Microlife AC adapter (DC 6V, 600 mA).Only use the original available MicrolifeAC adapter for your supply voltage.Check that both the AC adapter and the cable are notdamaged.1. Plug the adapter cable into the AC adapter connection 6 of theblood pressure monitor.2. Plug the AC adapter plug into the wall socket.When the AC adapter is connected, no battery power is used.For an explanation of error messages in the device, please refer to the package leaflet/manual.Safety, maintenance, accuracy test and disposalFollow the instructions for correct use. This documentation provides you with important operating and safety instructions concerning this device. Read the documentation carefully before using the device and keep it for future reference.This device may only be used for the purpose described in the instructions for use. The manufacturer cannot be held liable for damage caused by improper use.This device contains sensitive components and must be handled with care. Observe the storage and operating instructions, as described in the chapter«Technical specifications»!The cuff is fragile and must be handled with care.Only inflate the cuff when it is on the arm.Do not use the device if you suspect it is damaged or if you notice anything unusual during use.Never open the device.Read the further safety instructions in the separate paragraphs of this booklet.The measured results with this device do not constitute a diagnosis.It does not replace a doctor's consultation, especially not ifsymptoms do not match. Do not rely solely on themeasurement result, always take other symptoms into account, as well as the feedback.Allow children to use the device only under adult supervision. Small parts can be swallowed. Be aware of the risk of entanglement if the device is equipped with cables or tubes.Device maintenanceClean the device only with a soft dry cloth.Clean the cuffThe cuff included with the device is washable.1. Remove the cuff connector 9 from the cuff tube ATand gently pull the bladder through the opening.2. Wash the cuff cover at no hotter than 30 °C.3. Dry the cuff with a dry cloth.4. Insert the bladder back into the cuff cover through the opening and gently flatten the bladder.5. Reattach the cuff connector to the cuff tube.
Warnings
Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
This device must only be used for the intended purpose described in these instructions for use. The manufacturer cannot be held liable for damage caused by improper application.
Do not change the patient's medication and treatment based on the result of one or more measurements. Changes in treatment and medication should only be
prescribed by a medical professional.
Inspect the device, cuff and other components for damage. DO NOT USE the device, cuff or components if they appear damaged or operate abnormally.
Prolonged interruption of blood flow reduces peripheral circulation and can cause tissue damage. Watch for signs (e.g. tissue discoloration) of impaired peripheral circulation if you are taking continuous or prolonged measurements.
Prolonged exposure to cuff pressure will reduce peripheral perfusion and may lead to injury. Avoid situations of prolonged cuff pressure beyond normal measurements.
In the event of abnormally prolonged pressure, stop the measurement or loosen the cuff to reduce pressure in the cuff.
Do not use this device in an oxygen-rich environment or near flammable gas.
The device is not water-resistant or waterproof. Do not spill on the device and do not immerse it in water or other liquids.
Do not disassemble the device, accessories and components or attempt to repair it during use or storage.
Access to the internal hardware and software of the device is prohibited. Unauthorized access to and maintenance of the device during use or storage can compromise the safety and performance of the device.
Keep the device away from children and individuals who cannot operate the device. Be aware of the risks of accidental ingestion of small parts and strangulation with the cables and tubes of this device and accessories.
Indicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury to the user or patient, or damage to the device or other property.
The device is only intended for measuring blood pressure on the upper arm. Do not measure other sites, as the measurement will then not accurately reflect your blood pressure.
After a measurement is completed, loosen the cuff and rest for > 5 minutes to restore limb perfusion before taking a new measurement.
Do not use this device simultaneously with other medical electrical (ME) equipment. This may cause malfunctions in the device or inaccuracies in the measurements.
Do not use this device near high-frequency (HF) surgical equipment, magnetic resonance imaging (MRI) equipment and computed tomography (CT) scanners.
This may cause malfunctions in the device and inaccuracies in the measurements.
Use and store the device, cuff and components under the temperature and humidity conditions specified in «Technical specifications». Use and storage of the device, cuff and components in conditions outside the range specified in «Technical
specifications» may result in device malfunction and compromise safe use.
Protect the device and accessories from the following to prevent damage to the device:
- water, other liquids and moisture
- extreme temperatures
- impact and vibration
- direct sunlight
- pollution and dust
- Stop using this device and cuff and consult your doctor if you experience skin irritation or discomfort
Information on electromagnetic compatibility
This device complies with EN60601-1-2: 2015 Electromagnetic
standard electromagnetic interference.
This device is not certified for use near
high-frequency (HF) medical equipment.
Do not use this device near strong electromagnetic fields and portable radio frequency communication devices (e.g. microwave ovens and mobile devices). When
using this device, maintain a minimum distance of 0.3 m from
such devices.
Storage advice
Storage conditions: -20 - +55 °C / -4 - +131 °F15-90 % maximum relative humidity
Medical device. Read the package leaflet before use.
Responsible for marketing
Retomed Health BV/Microlife