{"product_id":"microlife-thermometer-pen-10-seconden-flextip-mt200-1-stuks","title":"Microlife Thermometer Pen 10 Seconds Flex-Tip MT200 1.00 Piece","description":"\u003cstrong\u003eMicrolife Thermometer pen 10 seconds flextip MT200\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eMicrolife Thermometer pen 10 seconds flextip MT200\u003cbr\u003e\u003cbr\u003eHigh-Speed Digital thermometer\u003cbr\u003e• Highest accuracy in 10 seconds\u003cbr\u003e• Flexible tip\u003cbr\u003e• Hypoallergenic tip\u003cbr\u003eTechnical specifications\u003cbr\u003eType: Maximum thermometer\u003cbr\u003eMeasurement range: 32.0 °C to 42.9 °C\u003cbr\u003eTemp. \u0026lt; 32.0 °C: display «L» for low (too low)\u003cbr\u003eTemp. \u0026gt; 42.9 °C: display «H» for high (too high)\u003cbr\u003eMeasurement accuracy: ± 0.1 °C between 34 °C and 42 °C\u003cbr\u003e± 0.2 °C; 32.0 - 33.9 °C and 42.1 - 42.9 °C\u003cbr\u003eOperating conditions: 10 - 40 °C; 15-95 % maximum relative humidity\u003cbr\u003eStorage conditions: -25 - +60 °C; 15-95 % maximum relative humidity\u003cbr\u003eBattery: LR41 (1.5V) \/ SR41 (1.55V)\u003cbr\u003eBattery life: approximately 2700 measurements (with a new battery)\u003cbr\u003eIP Class: IP67\u003cbr\u003eReference to standards: EN 12470-3, clinical thermometers;\u003cbr\u003eASTM E1112; IEC 60601-1; IEC 60601-1-2 (EMC);\u003cbr\u003eIEC 60601-1-11\u003cbr\u003eExpected lifespan: 5 years or 10000 measurements\u003cbr\u003e- clinically tested\u003cbr\u003eThis device complies with the standards of the Medical\u003cbr\u003eDevices Directive 93\/42\/EEC.\u003cbr\u003eTechnical modifications reserved\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003cbr\u003eMeasuring body temperature\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInstructions for use\u003c\/strong\u003e\u003cbr\u003eTurning on the thermometer\nTo turn on the thermometer, press the ON\/OFF button 1; a\nshort beep indicates that the thermometer is switched on. A display test\nis performed. All functions are displayed.\nThe last measurement will automatically be shown on display 2\nfor 2 seconds with the «M» symbol.\nAt a room temperature of less than 32 °C, the symbol «L» first appears\non the display, then the symbol «°C» flashes on\nthe display 2. The thermometer is now ready for use.\nFunction test\nThe operation of the thermometer is automatically tested every time\nit is switched on. If a defect is detected\n(inaccurate measurement), this is indicated by «ERR» on the\ndisplay, and measurement is then no longer possible. In this case, the thermometer\nmust be replaced.\n\nUsing the thermometer\nChoose the desired measurement method. During measurement, the current\ntemperature is continuously displayed and the «°C» symbol flashes.\nIf a beep sounds 10 times and the «°C» no longer flashes, the\ntemperature has been measured and can be read.\nIf the temperature is higher than 37.5 °C, 10 beeps will sound\nto alert the patient that they may have a fever.\nReference: Oral temperature measurement.\nTo compare measurement results, you should measure at intervals of at least 1 minute.\nTo extend battery life, you can turn off the thermometer\nby briefly pressing the ON\/OFF button 1. Otherwise, the\nthermometer will automatically switch off after approximately 10 minutes.\n\nMeasurement methods \/ Normal body temperature\n Under the armpit (axillary) \/ 34.7 - 37.3 °C\nPat the armpits dry with a towel. Place the measurement sensor\n4 under the arm in the middle of the armpit, so that the tip touches the skin\nand place the arm next to the body. This ensures that the\nroom temperature does not affect the measurement, as the armpit needs more\ntime to reach a temperature. Wait 5 minutes,\nregardless of the beep.\n In the mouth (oral) \/ 35.5 - 37.5 °C\nDo not eat or drink anything hot or cold 10 minutes before the measurement. The mouth\nshould remain closed until 2 minutes before starting the measurement.\nPlace the thermometer under the tongue, to the left or right of the frenulum.\nThe tip of the thermometer must have good contact with\nthe tissue 4. Close the mouth and breathe evenly through the nose to\nprevent the measurement from being affected by mouth breathing.\nIf this is not possible due to blocked airways, a\ndifferent measurement method should be used.\nMeasurement time approx.: 10 seconds!\n In the anus (rectal) \/ 36.6 - 38.0 °C\nCarefully insert the measurement sensor of the thermometer 4 2 to 3 cm\ninto the anal opening.\nThe use of a protective cap and petroleum jelly is recommended.\nIf you are unsure about this measurement method, consult a professional\nfor guidance \/ training.\nMeasurement time approx.: 10 seconds!\n\nCleaning and disinfection\nFor disinfection in a home environment, use a cotton swab moistened with\n70% isopropyl alcohol or a cotton cloth moistened with\n70% isopropyl alcohol to wipe dirt from the thermometer probe\n (note: consider the application and safety instructions of\nthe disinfectant manufacturer). Always start wiping\nfrom the end of the thermometer probe (approximately in the middle\nof the thermometer) towards the thermometer tip. Then, the\nentire thermometer probe (see number 5 in the drawing) should be\nimmersed in 70% isopropyl alcohol for at least 70% 5\nminutes (max. 24 hours). After immersion, allow the disinfectant to dry\nfor 1 minute before the next use. Do not immerse or wipe the\nscreen to prevent fading.\nThe thermometer is not intended for professional use.\n\nWhen the symbol «» appears on the display, the battery\nis empty and must be replaced. To replace the battery, the cover of the battery compartment\nmust be removed 3. Insert a new battery with the + on top.\nMake sure you have a battery of the same type handy. Batteries can be bought in almost\nall electronics stores.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eWarnings\u003c\/strong\u003e\u003cbr\u003eFollow the instructions for correct use. This documentation provides you with important operating and safety regulations concerning this device. Read the documentation carefully before operating the device and keep it for future reference.\u003cbr\u003e- This device may only be used for measuring human body temperature via oral, rectal, or axillary means.\u003cbr\u003eDo not attempt to take temperatures at other sites, such as in the ear, as this may lead to inaccurate readings and injury.\u003cbr\u003e- Do not use this device if you suspect it is damaged or if you have noticed anything unusual.\u003cbr\u003e- We recommend cleaning this device according to the cleaning instructions before first use for personal hygiene.\u003cbr\u003e- The measurement time until the acoustic signal must be adhered to without exception!\u003cbr\u003e- Please note that for different measurement locations, even after the beep, multiple measurements may be necessary\u003cbr\u003e- Do not attempt rectal measurements on individuals with rectal disorders. This may worsen the condition.\u003cbr\u003e- Allow children to use the device only under adult supervision. Small parts can be swallowed. Be aware of the risk of entanglement if the device is equipped with cables or tubes.\u003cbr\u003e- Do not use the device near strong electromagnetic fields such as mobile phones or radio installations. Maintain a distance of at least 3.3 meters from such devices when operating this device.\u003cbr\u003e- Protect the instrument from shocks and drops!\u003cbr\u003e- Do not bend the thermometer probe more than 45°!\u003cbr\u003e- Avoid ambient temperatures above 60 °C. NEVER boil the instrument!\u003cbr\u003e- Use only the disinfectants listed in the Cleaning and Disinfection section to clean the device to prevent damage to the device.\u003cbr\u003e- We recommend having this device checked for accuracy every two years or after mechanical impact (e.g., dropping). Contact your local Microlife dealer for this.\u003cbr\u003e\u003cbr\u003eWARNING: The temperature measured with this device is not a diagnosis! Therefore, do not rely solely on the measured result.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003e Storage advice \u003c\/strong\u003e\u003cbr\u003eBatteries and electronic instruments must be disposed of according to local regulations, not with household waste.\n\nStore at a temperature between -25°C and 60°C\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eSuitable for children from\u003c\/strong\u003e\u003cbr\u003e0\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eOther information\u003c\/strong\u003e\u003cbr\u003eWarranty\u003cbr\u003eThis device has a lifetime warranty from the date of purchase.\u003cbr\u003eDuring this warranty period, Microlife will repair or replace the defective product free of charge.\u003cbr\u003eOpening or modifying the device invalidates the warranty.\u003cbr\u003eThe following items are excluded from warranty:\u003cbr\u003e- Shipping costs and shipping risks.\u003cbr\u003e- Damage caused by improper use or non-compliance with the operating instructions.\u003cbr\u003e- Damage caused by leaking batteries.\u003cbr\u003e- Damage caused by dropping or misuse.\u003cbr\u003e- Packaging \/ storage material and operating instructions.\u003cbr\u003e- Regular checks and maintenance (calibration).\u003cbr\u003e- Accessories and consumables: Battery.\u003cbr\u003eIf warranty is required, please contact the dealer where you purchased the product, or your local Microlife service.\u003cbr\u003e\u003cbr\u003eYou can contact your local Microlife dealer via our website:\u003cbr\u003ewww.microlife.com\/support\u003cbr\u003eCompensation is limited to the value of the product. The warranty is granted if the complete product is returned with the original invoice. Repair or replacement under warranty does not extend the warranty period. The legal claims and rights of consumers are not limited by this warranty.\u003cbr\u003e\u003cbr\u003eMedical device. Read the leaflet before use.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eResponsible for placing on the market\u003c\/strong\u003e\u003cbr\u003eRetomed Health BV\/Microlife","brand":"Microlife","offers":[{"title":"1.00 Piece","offer_id":61773036323146,"sku":"788909","price":11.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0924\/5497\/7866\/files\/4719003070021_A1N1_74864374-71dc-41c8-a831-0e220d0e8e07.png?v=1781796878","url":"https:\/\/ithomepharma.com\/en\/products\/microlife-thermometer-pen-10-seconden-flextip-mt200-1-stuks","provider":"AtHomePharma","version":"1.0","type":"link"}