{"product_id":"microlife-non-contact-thermometer-nc200-1-stuks","title":"Microlife Non-contact thermometer NC200 1.00 Piece","description":"\u003cstrong\u003eMicrolife Non-contact thermometer NC200\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eThis Microlife thermometer is a high-quality product incorporating the latest technology and tested according to international standards. With its unique technology, this thermometer can provide a stable reading free from heat interference with each measurement. Each time the thermometer is switched on, the device automatically performs a self-test to ensure the accuracy of the measurements.\u003cbr\u003e\u003cbr\u003eThis thermometer has been clinically tested, found to be safe and accurate when used in accordance with its instructions for use.\u003cbr\u003e\u003cbr\u003eTechnical specifications\u003cbr\u003eType: Adapted mode non-contact thermometer NC 200\u003cbr\u003eMode type: Adjustable mode\u003cbr\u003eMeasurement location: Forehead\u003cbr\u003eReference body site: Under the tongue\u003cbr\u003eMeasurement range: Body mode: 34.0 - 43.0 °C \/ 93.2 - 109.4 °F\u003cbr\u003eObject mode: 0.1 - 99.9 °C \/ 32.2 - 211.8 °F\u003cbr\u003eResolution: 0.1 °C \/ °F\u003cbr\u003eStorage conditions: -25 - +55 °C \/ -13 - +131 °F\u003cbr\u003e15 - 95 % maximum relative humidity\u003cbr\u003eAutomatic shutdown: Approximately 1 minute after the last measurement.\u003cbr\u003eBattery: 2 x 1.5V alkaline batteries; type AAA\u003cbr\u003eBattery life: approximately 2000 measurements (with new batteries)\u003cbr\u003eDimensions: 156.7 x 43 x 47 mm\u003cbr\u003eWeight: 91.5 g (with battery), 68.5 g (without battery)\u003cbr\u003eIP Class: IP22\u003cbr\u003eReference to\u003cbr\u003estandards: ISO 80601-2-56; IEC 60601-1; IEC 60601-1-2 (EMC)\u003cbr\u003eExpected lifespan: 5 years or 12000 measurements\u003cbr\u003e- Measure in seconds\u003cbr\u003e- The innovative infrared technology allows a measurement to be completed without contact with the body. This guarantees\u003cbr\u003ea safe and hygienic measurement in seconds.\u003cbr\u003e- Automatic measurement with distance control\u003cbr\u003eThis device can automatically take a measurement when the\u003cbr\u003edesired distance within 5 cm is reached.\u003cbr\u003e- Multiple applications (wide measurement range)\u003cbr\u003eThis thermometer has a wide measurement range of 0.1 - 99.9 °C \/\u003cbr\u003e32.2 - 211.8 °F; the thermometer can be used to measure\u003cbr\u003ebody temperature, but can also be used\u003cbr\u003efor measuring the surface temperature of:\u003cbr\u003e- Milk in a baby's bottle\u003cbr\u003e- Water in a baby's bath\u003cbr\u003e- Ambient temperature\u003cbr\u003e\u003cbr\u003eAccurate and reliable\u003cbr\u003eThe unique probe head with built-in advanced infrared sensor ensures that every measurement is accurate and reliable.\u003cbr\u003e\u003cbr\u003eUser-friendly and easy to use\u003cbr\u003e- The ergonomic design makes the thermometer easy to handle and use.\u003cbr\u003e- This thermometer can even be used on a sleeping child, who can continue sleeping peacefully.\u003cbr\u003e- This thermometer is fast and therefore pleasant to use for children\u003cbr\u003e- Recall multiple readings\u003cbr\u003e- Users can consult the last 30 measurements by activating the memory mode. This allows you to easily\u003cbr\u003emonitor temperature variations.\u003cbr\u003e\u003cbr\u003eSafe and hygienic\u003cbr\u003e- No direct contact with the skin.\u003cbr\u003e- No risk of broken glass or mercury ingestion.\u003cbr\u003e- Completely safe for children.\u003cbr\u003e\u003cbr\u003eFever alarm\u003cbr\u003e- 10 short beeps and a red illuminated LCD alert you that a temperature above 37.5 °C has been measured.\u003cbr\u003e- Tracking system for a self-measurement\u003cbr\u003e- A green light on the back shows the user if the correct distance has been reached and a measurement is performed automatically.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eUsage\u003c\/strong\u003e\u003cbr\u003eThe Microlife thermometer is intended for measuring and monitoring human body temperature.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInstructions for use\u003c\/strong\u003e\u003cbr\u003eTaking temperature with this thermometer\nThe thermometer measures the infrared radiation emitted by the forehead or other objects. This energy is collected by the lens and converted into a temperature value.\n\nControl screen and symbols\nAll symbols appear 9: Press the START\/IO button to activate the thermometer, all symbols will appear on the screen for 1 second.\nReady for measurement AT: When the thermometer is ready for measurement, the «°C» or «°F» symbol will continue to flash, while the body or object symbol is permanently displayed.\nCountdown for measurement BR: A 3-second countdown is shown on the display (3, 2, 1) before each measurement.\nMeasurement completed AK: The measurement will be shown on display 4 while both the ear or forehead symbol and the «°C» or «°F» symbol are permanently displayed.\nOnce the «°C» or «°F» symbol flashes again, the device is ready for the next measurement\nLow battery AN: If the thermometer is switched on, the icon will continue to flash to remind you to replace the batteries.\n\nSetting date, time and beeper functions\nSetting the date and time\nAfter the batteries are inserted, the year flashes on the display BO. You can set the year by pressing the M button 5. To confirm and then set the month, press the MODE button 6.\nNow you can set the month with the M button 5. Press the MODE button 6 to confirm and then set the day.\nFollow the instructions as described above to set the day, hours and minutes.\nOnce you have set the minutes and pressed the START\/IO button 7, the date and time are set and the time is displayed.\nIf no button is pressed for 20 seconds, the thermometer automatically switches to the ready for use state AT.\nEnd time set-up: Press the START\/IO button 7 during time set-up. The LCD screen will show Date\/time symbol with «--:--». Then press the START\/IO button 7 to start the measurement. If you do nothing further, the thermometer will automatically switch off after 30 seconds.\nChange current date and time: Press and hold the MODE button 6 for 8 seconds, so that the year starts flashing BO. Now you can enter the new data as described above.\n\nBeeper setting\nPress and hold the MODE button 6 for 3 seconds to set the beeper BP.\nPress the M button 5 to turn the beeper on or off. The beeper is activated when the sound symbol BP is shown without a cross.\nWhen the beeper setting is chosen, press the START\/IO button 7 for the «ready for measurement» mode; otherwise, the device will automatically be ready for measurement after 10 seconds.\n\nSwitching from body mode to object mode\nPress the START\/IO button 7. All symbols appear on screen 4 for 1 second.\nThe default mode is object mode AL. Press the MODE button 6 to switch modes AM. To switch back to body mode, press the MODE button again.\n\nInstructions for use\nAlways remove the protective cap BS before use.\nMeasuring in body mode with automatic measurement and distance control\n1. Press the START\/IO button 7. All symbols appear on screen 4 for 1 second.\n2. A flashing «°C»\/«°F» symbol, a blue flashing tracking light 2, and a beep indicate that the device is ready for a measurement AT.\n3. Remove hair, sweat, or dirt from the forehead to prevent inaccurate readings.\n4. Aim the thermometer at the center of the forehead, keeping a distance of no more than 5 cm from the forehead.\n5. The device will start automatically when the measurement sensor 1 detects the required distance of less than 5 cm. The display will show a countdown (3, 2, 1); after 3 seconds, a long beep will indicate that the measurement is complete.\n6. Self-measurement: The self-measurement light 3 will help indicate when the measurement starts. Keep the thermometer aimed at the forehead until the light turns off.\n7. Read the measured temperature from the LCD display.\n8. For a subsequent measurement, move the thermometer away from the forehead and wait until the «°C»\/«°F» symbol flashes again. Then proceed with step 4 - 5 above.\n9. Press and hold the START\/IO button 7 for 3 seconds to turn it off; otherwise, the device will automatically turn off after 60 seconds.\nMeasuring in object mode without automatic measurement 1. Press the START\/IO button 7. All symbols appear on screen 4 for 1 second.\n2. Press the MODE button 6 to switch to object mode.\n3. A flashing «°C»\/«°F» symbol, a blue flashing tracking light 2, and a beep indicate that the device is ready for a measurement AT.\n4. Aim the thermometer at the center of the object you want to measure, at a distance of no more than 5 cm. Now press the START\/IO button 7. After 3 seconds, a long beep will indicate that the measurement is complete.\n5. Read the measured temperature from the LCD display.\n6. For a subsequent measurement, wait until the «°C»\/«°F» symbol flashes again. Then proceed with step 4 - 5 above.\n7. Press and hold the START\/IO button 7 for 3 seconds to turn it off; otherwise, the device will automatically turn off after 60 seconds.\nPatients and thermometer must remain in a room with a constant temperature for at least 30 minutes.\nDo not measure during or immediately after feeding a baby.\nDo not use the thermometer in rooms with excessively high humidity.\nPatients should not drink, eat, or exercise before\/during measurement.\nDo not remove the measuring device from the measurement area until you have heard the final beep.\n10 short beeps and a red illuminated LCD will alert you that a temperature above 37.5 °C has been measured.\nAlways take the temperature at the same location, as temperature readings can vary from place to place.\nDoctors recommend taking the temperature rectally in newborns for the first 6 months, as other measurement methods can often lead to unreliable results. If you still want to perform a non-contact measurement in newborns, check this with a rectal measurement.\nIn the following circumstances, it is recommended to take three measurements and use the highest result:\nChildren younger than three years with a deficient immune system and for whom the presence or absence of fever is critical.\nWhen the user is first learning to use the thermometer, until he\/she is familiar with the device and obtains consistent results.\nIf the measurement result is unexpectedly low.\nTemperature measurements should not be compared with each other, as body temperature can fluctuate due to time and ambient temperature; body temperature is often highest in the evening and lowest in the morning.\n\nNormal body temperatures are:\nAxillary: 34.7 - 37.3 °C \/ 94.5 - 99.1 °F\nOral: 35.5 - 37.5 °C \/ 95.9 - 99.5 °F\nRectal: 36.6 - 38.0 °C \/ 97.9 - 100.4 °F\nMicrolife NC 200: 35.4 - 37.4 °C \/ 95.7 - 99.3 °F\n\n8. Switchable from Celsius to Fahrenheit\nThis thermometer displays temperature measurements in Fahrenheit and Celsius. To switch between °C and °F, press and hold the MODE button 6 for 3 seconds; the beeper symbol will be displayed. Press the MODE button again; the current unit of measurement («°C» or «°F» symbol) will be displayed AO. Switch between the units of measurement (°C\/°F) by pressing the M button 5. When the unit of measurement is selected, press the START\/IO button 7 to activate «ready for measurement»; otherwise, the device will automatically switch off after 10 seconds AT.\n\n9. Recalling 30 measurements in memory mode\nThis thermometer displays the last 30 measurements, including date and time.\nRecall mode AP: Press the M button 5 to enter recall mode when the device is off. The memory symbol «M» flashes.\nResult 1 – the last result AQ: Press the M button 5\nand release it to see the last result. Screen 1\nonly with memory symbol.\nBy pressing and releasing the M button 5 after the past 30 results have been recalled, the sequence above will resume with result 1.\n\n10. Error messages\nMeasured temperature too high AR: The symbol «H» will\nappear if the temperature is higher than 43 °C \/ 109.4 °F in\nbody mode or 99.9 °C \/ 211.8 °F in object mode.\nMeasured temperature too low AS: The symbol «L» will\nappear if the temperature is lower than 34 °C \/ 93.2 °F in\nbody mode or 0.1 °C \/ 32.2 °F in object mode.\n\nAmbient temperature too high BT: The symbol «AH» will appear when the ambient temperature is higher than\n40.0 °C \/ 104.0 °F.\nAmbient temperature too low BK: The symbol «AL» will appear when the ambient temperature is lower than 15.0\n°C \/ 59.0 °F in body mode or lower than 5.0 °C \/ 41.0 °F in object mode.\n\nOperating error BL:\n«Er 0» \/ «Er 6»: The system is not working properly.\n«Er 2»: The device is placed directly on the forehead or object. Keep a distance of 1 - 5 cm. Never touch the underside (sensor area) of the measurement sensor.\nBlank screen BM: Please check if the batteries are inserted correctly. Also check the polarity (\u0026lt;+\u0026gt; and \u0026lt;-\u0026gt;) of the batteries.\nLow battery BN: If only the icon is displayed, replace the batteries immediately.\n\n11. Cleaning and disinfection\nUse a cotton swab or cotton wool soaked in alcohol (70% isopropyl) to clean the thermometer casing and probe head. Make sure no liquid enters the inside of the thermometer. Never use aggressive cleaning agents, thinners or benzene for cleaning, and never immerse the thermometer in water or any other liquid. Make sure that the surface of the probe lens and the screen are not scratched.\n\n12. Battery replacement\nThis instrument comes with 2 long-life 1.5V AAA batteries, which must be replaced immediately if only the symbol BN is displayed.\nRemove the battery cover BQ by pushing in the indicated direction.\nReplace the batteries – check the correct polarity as shown by the symbols in the compartment.\nBatteries and electronic instruments must be disposed of according to local regulations, not with household waste.\n\nSee the leaflet for button labels and locations.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eWarnings\u003c\/strong\u003e\u003cbr\u003eFollow the instructions for correct use. This documentation provides important operating and safety instructions concerning this device. Read the documentation carefully before using the device and keep it for future reference.\u003cbr\u003e\u003cbr\u003eThis device may only be used for the purpose described in the instructions for use. The manufacturer cannot be held liable for damage caused by improper use.\u003cbr\u003e\u003cbr\u003eNever immerse this device in water or other liquids. For cleaning, follow the instructions in the «Cleaning and disinfection» paragraph.\u003cbr\u003e\u003cbr\u003eDo not use the device if you suspect it is damaged or if you notice anything unusual during use.\u003cbr\u003e\u003cbr\u003eNever open the device.\u003cbr\u003e\u003cbr\u003eA normal biological process called vasoconstriction can occur in an early stage of fever, resulting in a lower skin surface temperature; the measured temperature with a thermometer may then be suspiciously low.\u003cbr\u003e\u003cbr\u003eIf the measurement result is not consistent with the patient's findings or suspiciously low, repeat the measurement every 15 minutes or check the result with another core body temperature measurement.\u003cbr\u003e\u003cbr\u003eThis device contains sensitive components and must be handled with care. Observe the storage and operating instructions as described in the chapter «Technical specifications»!\u003cbr\u003e\u003cbr\u003eAllow children to use the device only under adult supervision; small parts can be swallowed.\u003cbr\u003e\u003cbr\u003eDo not use the device near strong electromagnetic fields such as mobile phones or radio installations. Ensure a distance of at least 3.3 meters from such devices when operating this device.\u003cbr\u003e\u003cbr\u003eProtect it from:\u003cbr\u003e- extreme temperatures\u003cbr\u003e- shocks and drops\u003cbr\u003e- dirt and dust\u003cbr\u003e- direct sunlight\u003cbr\u003e- heat and cold\u003cbr\u003e- If the device is not going to be used for a longer period of time,\u003cbr\u003ethe batteries must be removed.\u003cbr\u003e\u003cbr\u003eWARNING: The measured results with this device do not constitute a diagnosis. It does not replace a consultation\u003cbr\u003ewith a doctor, especially if the symptoms do not match. Do not rely solely on the measurement result, always consider other symptoms, as well as patient feedback. If in doubt, always contact your doctor.\u003cbr\u003e\u003cbr\u003eMedical device. Read the leaflet before use.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eResponsible for marketing\u003c\/strong\u003e\u003cbr\u003eRetomed Health BV\/Microlife","brand":"Microlife","offers":[{"title":"1.00 Piece","offer_id":61988844634442,"sku":"225702","price":47.03,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0924\/5497\/7866\/files\/4719003402914_A1N1.png?v=1790776469","url":"https:\/\/ithomepharma.com\/en\/products\/microlife-non-contact-thermometer-nc200-1-stuks","provider":"AtHomePharma","version":"1.0","type":"link"}