{"product_id":"microlife-mic-bpb3-basic-bloeddrukmonitor-1-stuks","title":"Microlife MIC BPB3 Basic Blood Pressure Monitor 1 Piece","description":"\u003cb\u003eMicrolife MIC BPB3 Basic blood pressure monitor\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eMicrolife MIC BPB3 Basic blood pressure monitor\u003cbr\u003eOperating conditions: 10 - 40 °C \/ 50 - 104 °F\u003cbr\u003e15-90 % maximum relative humidity\u003cbr\u003eWeight: 277 g (including batteries)\u003cbr\u003eDimensions: 131 x 90 x 60.5 mm\u003cbr\u003eCuff dimensions: from 17 - 52 cm\u003cbr\u003eMeasuring procedure: oscillometric, according to the Korotkoff\u003cbr\u003emethod: Phase I systolic Phase V diastolic\u003cbr\u003eMeasuring range: SYS: 60 - 255 mmHg\u003cbr\u003eDIA: 40 - 200mmHg\u003cbr\u003ePulse: 40 - 199 beats per minute\u003cbr\u003eCuff pressure display range: 0 - 299 mmHg\u003cbr\u003eResolution: 1 mmHg\u003cbr\u003eStatic accuracy: within ± 3 mmHg\u003cbr\u003eHeart rate accuracy: ±5 % of the displayed value\u003cbr\u003ePower source: 4 x 1.5V alkaline batteries; type AA\u003cbr\u003eMains adapter DC 6V, 600 mA (optional)\u003cbr\u003eBattery life: approximately 920 measurements (with new\u003cbr\u003ebatteries)\u003cbr\u003eIP Class: IP 20\u003cbr\u003eReference to standards:\u003cbr\u003eIEC 80601-2-30; IEC 60601-1;\u003cbr\u003eIEC 60601-1-2 (EMC); IEC 60601-1-11\u003cbr\u003e\u003cbr\u003eExpected lifespan:\u003cbr\u003eDevice: 5 years or 10000 measurements, whichever comes first.\u003cbr\u003eAccessories: 2 years or 5000 measurements, whichever comes first\u003cbr\u003e\u003cbr\u003eThis device complies with the standards of the Medical Devices Directive 93\/42\/EEC.\u003cbr\u003eTechnical modifications reserved.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWhat is this product used for\u003c\/b\u003e\u003cbr\u003eMeasuring blood pressure.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eInstructions for use\u003c\/b\u003e\u003cbr\u003eInserting the batteries\u003cbr\u003eAfter unpacking the device, first insert the batteries.\u003cbr\u003eThe battery compartment 7 is located on the underside of\u003cbr\u003ethe device. Insert the batteries (4 x 1.5 V, size AA), paying attention to\u003cbr\u003ethe indicated polarity.\u003cbr\u003e\u003cbr\u003eSetting date and time\u003cbr\u003e1. After the batteries are inserted, the year flashes on the screen. You can set the year by pressing the M button 3. To confirm and then set the month, press the time button 4.\u003cbr\u003e2. Now you can set the month with the M button. Press the time button to confirm and then set the day.\u003cbr\u003e3. Follow the instructions above to set day, hour and minutes.\u003cbr\u003e4. Once you have set the minutes and pressed the time button, the date and time are set and the time is displayed.\u003cbr\u003e5. If you want to change the date and time, hold down the time button for approx. 3 seconds until the year starts flashing. Now you can enter new values as described above.\u003cbr\u003e\u003cbr\u003eSelect the correct cuff\u003cbr\u003eMicrolife has cuffs in different sizes. Select the cuff size that corresponds to your upper arm circumference (the measured circumference around the middle of the upper arm).\u003cbr\u003eContact your Microlife importer if the included cuff 8 does not fit.\u003cbr\u003eAttach the cuff to the device using the cuff connector 9, pushing the connector 5 as far as possible into the device.\u003cbr\u003e\u003cbr\u003eCuff size for upper arm circumference\u003cbr\u003eS 17 - 22 cm\u003cbr\u003eM 22 - 32 cm\u003cbr\u003eM - L 22 - 42 cm\u003cbr\u003eL 32 - 42 cm\u003cbr\u003eL - XL 32 - 52 cm\u003cbr\u003e\u003cbr\u003ePre-formed cuffs are optionally available.\u003cbr\u003eUse only Microlife cuffs!\u003cbr\u003e\u003cbr\u003eStep-by-step plan for reliable blood pressure measurement\u003cbr\u003eAvoid activity, eating or smoking just before a measurement.\u003cbr\u003eSit on a chair with back support and relax for 5 minutes.\u003cbr\u003eKeep your feet together on the floor and do not sit with your legs crossed.\u003cbr\u003eAlways measure on the same arm (normally the left). It is recommended that doctors measure both arms during a patient's first visit to determine the arm to be measured. The arm with the higher blood pressure should be measured.\u003cbr\u003eRemove clothing covering the upper arm; sleeves should not be rolled up to avoid constriction.\u003cbr\u003eAlways ensure that the correct cuff size is used (arm circumference marking is indicated on the cuff).\u003cbr\u003eAttach the cuff to the arm, but not too tightly.\u003cbr\u003eEnsure the cuff is placed 1-2 cm above your elbow.\u003cbr\u003eThe artery mark on the cuff (approx. 3 cm long bar) should be placed over the artery of the arm (inside).\u003cbr\u003eSupport your arm so it is relaxed.\u003cbr\u003eEnsure the cuff is at the same height as your heart.\u003cbr\u003e\u003cbr\u003eMeasuring blood pressure\u003cbr\u003e1. Press the ON\/OFF button 1 to start the measurement.\u003cbr\u003e2. The cuff will now inflate automatically. Relax,\u003cbr\u003edo not move, and do not tense your arm muscles until the measurement result is shown. Breathe normally and do not talk.\u003cbr\u003e3. If the cuff is correctly placed, the Cuff check indicator AR symbol will appear on the screen. If the symbol\u003cbr\u003eCuff position check AR-A appears, the cuff is\u003cbr\u003emoderately placed, but a correct blood pressure measurement can still be performed.\u003cbr\u003e4. When the correct pressure is reached, pumping stops and the pressure slowly decreases. If the desired pressure is not reached, the device will automatically pump more air into the cuff.\u003cbr\u003e5. During the measurement, the heart symbol AQ will flash on the screen.\u003cbr\u003e6. The result, including the systolic AK and diastolic AL blood pressure and the pulse rate AM, will be displayed.\u003cbr\u003eAlso refer to this manual for an explanation of the other displays.\u003cbr\u003e7. When the measurement is complete, remove the cuff.\u003cbr\u003e8. Switch off the device. (The monitor automatically turns off after approx. 1 minute).\u003cbr\u003eYou can stop the measurement at any time by pressing the ON\/OFF button or opening the cuff (e.g. if you feel uncomfortable or experience unpleasant pressure).\u003cbr\u003eThis monitor has been specially tested for use during pregnancy and pre-eclampsia. If you record unusually high readings, you should repeat the measurement later (e.g. 1 hour). If the reading is still too high, consult your doctor or gynaecologist.\u003cbr\u003e\u003cbr\u003eManually setting inflation\u003cbr\u003eIn case of high systolic blood pressure (e.g. above 135 mmHg) it can be advantageous to set the pressure manually. Press the ON\/OFF button when the blood pressure monitor has inflated to approximately 30mmHg. Hold the button until the pressure is approximately 40 mmHg higher than the expected systolic value and then release the button.\u003cbr\u003e\u003cbr\u003ePerforming a measurement without saving it\u003cbr\u003eOnce the measurement is performed and the result is shown on the display, press and hold the ON\/OFF button 1 until the «M» AP appears on the display. Then press the time button 4 and the measurement will be deleted and not saved.\u003cbr\u003eWhen the measurement has been successfully deleted, «CL» will appear on the display.\u003cbr\u003e\u003cbr\u003eHow do I measure my blood pressure?\u003cbr\u003eThe triangular symbol on the left of the display AO refers to the classification of home blood pressure values in adults in accordance with international guidelines (ESH, ESC,\u003cbr\u003eJSH). The blood pressure value: Optimal (white), elevated (shaded grey) or too high (black). Values in mmHg.\u003cbr\u003e\u003cbr\u003eRange                  Systolic    Diastolic Advice\u003cbr\u003e1. blood pressure too high    \u0026gt;\/= 135       \u0026gt;\/= 85 Seek medical advice\u003cbr\u003e2. blood pressure elevated   130 - 134     80 - 84 Self-monitoring\u003cbr\u003e3. blood pressure normal    \u0026lt;130          \u0026lt;80 Self-monitoring\u003cbr\u003e\u003cbr\u003eThe evaluation of the values is according to the table. For example:\u003cbr\u003ea blood pressure value of 140\/80 mmHg or a value\u003cbr\u003eof 130\/90 mmHg indicates «blood pressure too high».\u003cbr\u003e\u003cbr\u003eAppearance of the irregular heartbeat (IHB) symbol\u003cbr\u003eThis symbol BT indicates that an irregular heartbeat has been\u003cbr\u003edetected. In this case, the measured blood pressure may deviate from\u003cbr\u003eyour actual blood pressure values. It is recommended to\u003cbr\u003erepeat the measurement.\u003cbr\u003e\u003cbr\u003eInformation for the physician in case of repeated\u003cbr\u003eappearance of the IHB symbol\u003cbr\u003eThis device is an oscillometric blood pressure monitor that also measures the\u003cbr\u003epulse during blood pressure measurement and indicates when the heart rate is irregular.\u003cbr\u003e\u003cbr\u003eMemory storage\u003cbr\u003eThis device stores the last 30 measurements.\u003cbr\u003e\u003cbr\u003eViewing stored values\u003cbr\u003ePress the M button 3 when the device is switched off. The display will first show «M» AP and «A», which stands for the average of all stored values.\u003cbr\u003ePressing the M button again will show the previous value. By pressing the M button again, you can scroll through the measurement results.\u003cbr\u003e\u003cbr\u003eClear all values\u003cbr\u003eIf you are sure you want to permanently delete all stored values, press and hold the M button (first switch off the device) until «CL ALL» appears and then release the button. To permanently clear the memory, press the time button while «CL ALL» is flashing. Individual measurements cannot be deleted.\u003cbr\u003e\u003cbr\u003eCancel deletion: press the ON\/OFF button 1 while «CL ALL» is flashing.\u003cbr\u003e\u003cbr\u003eBattery indicator and battery replacement\u003cbr\u003eBatteries almost empty\u003cbr\u003eWhen the batteries are approximately ¾ used, the battery symbol AN will flash as soon as the device is switched on\u003cbr\u003e(partially charged battery is displayed). Although the\u003cbr\u003edevice will continue to measure reliably, you should replace the batteries\u003cbr\u003esoon.\u003cbr\u003eBatteries empty – replacement\u003cbr\u003eWhen the batteries are empty, the battery symbol AN will flash as soon as the device is switched on (empty battery displayed). You cannot continue measuring and must replace the batteries.\u003cbr\u003e1. Open the battery compartment 7 at the back of the device.\u003cbr\u003e2. Replace the batteries – check the correct polarity as\u003cbr\u003eshown by the symbols in the compartment.\u003cbr\u003e3. To set the date and time, follow the procedure as\u003cbr\u003edescribed in Section «Initial use of the device».\u003cbr\u003e\u003cbr\u003eWhich batteries and which procedure?\u003cbr\u003eUse 4 new, long-life 1.5V, type AA alkaline batteries.\u003cbr\u003eDo not use batteries whose expiry date has\u003cbr\u003epassed.\u003cbr\u003eRemove the batteries if the device will not be used for a longer\u003cbr\u003eperiod of time.\u003cbr\u003e\u003cbr\u003eUse of rechargeable batteries\u003cbr\u003eYou can also use rechargeable batteries for this device.\u003cbr\u003ePlease use only «NiMH» type rechargeable batteries!\u003cbr\u003eThe batteries must be removed and recharged if\u003cbr\u003ethe battery symbol (low battery) appears! They should not\u003cbr\u003eremain in the device, as they can be damaged\u003cbr\u003e(complete discharge due to minimal use\u003cbr\u003eof the device, even when switched off).\u003cbr\u003eAlways remove rechargeable batteries if you do not plan\u003cbr\u003eto use the device for a week or longer!\u003cbr\u003eThe batteries CANNOT be recharged in the blood pressure monitor! Charge these batteries in an external\u003cbr\u003echarger and adhere to the information regarding\u003cbr\u003echarging, maintenance and durability!\u003cbr\u003e\u003cbr\u003eUse of a mains adapter\u003cbr\u003eYou can use this device with the Microlife mains adapter (DC 6V, 600 mA).\u003cbr\u003eOnly use the original available Microlife\u003cbr\u003emains adapter for your power voltage.\u003cbr\u003eCheck that both the mains adapter and the cable are not\u003cbr\u003edamaged.\u003cbr\u003e1. Plug the adapter cable into the mains adapter socket 6 of the\u003cbr\u003eblood pressure monitor.\u003cbr\u003e2. Plug the mains adapter plug into the wall socket.\u003cbr\u003eWhen the mains adapter is connected, no battery power is used.\u003cbr\u003e\u003cbr\u003eFor an explanation of error messages in the device, please refer to the leaflet\/manual.\u003cbr\u003e\u003cbr\u003eSafety, maintenance, accuracy test and disposal\u003cbr\u003eFollow the instructions for correct use. This documentation provides you with important operating and safety instructions regarding this device. Read the documentation carefully before using the device and keep it for future reference.\u003cbr\u003eThis device may only be used for the purpose described in the user manual. The manufacturer cannot be held liable for damage caused by incorrect use.\u003cbr\u003eThis device contains sensitive components and must be handled with care. Observe the storage and operating instructions as described in the chapter\u003cbr\u003e\u003cbr\u003e«Technical specifications»!\u003cbr\u003eThe cuff is fragile and must be handled with care.\u003cbr\u003eOnly inflate the cuff when it is applied to the arm.\u003cbr\u003eDo not use the device if you suspect it is damaged or if you notice anything unusual during use.\u003cbr\u003eNever open the device.\u003cbr\u003eRead further safety instructions in the individual sections of this booklet.\u003cbr\u003eThe measured results with this device do not constitute a diagnosis.\u003cbr\u003eIt does not replace a doctor's consultation, especially if\u003cbr\u003esymptoms do not match. Do not rely solely on the\u003cbr\u003emeasurement result, always consider other symptoms, as well as feedback.\u003cbr\u003e\u003cbr\u003eChildren should only use the device under adult supervision. Small parts can be swallowed. Be aware of the risk of entanglement if the device has cables or tubes.\u003cbr\u003e\u003cbr\u003eDevice maintenance\u003cbr\u003eClean the device only with a soft dry cloth.\u003cbr\u003eClean the cuff\u003cbr\u003eThe cuff supplied with the device is washable.\u003cbr\u003e1. Remove the cuff connector 9 from the cuff tube AT\u003cbr\u003eand gently pull the bladder through the opening.\u003cbr\u003e2. Wash the cuff cover at no warmer than 30 °C.\u003cbr\u003e3. Dry the cuff with a dry cloth.\u003cbr\u003e4. Insert the bladder back into the cuff cover through the opening and gently flatten the bladder.\u003cbr\u003e5. Reattach the cuff connector to the cuff tube.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eContraindications\u003c\/b\u003e\u003cbr\u003eDo not use this device if the patient's condition meets the following contraindications, to avoid inaccurate measurements or injury.\u003cbr\u003eThe device is not intended for measuring blood pressure in paediatric patients under 12 years of age (children, infants or neonates).\u003cbr\u003eThe presence of significant cardiac arrhythmias during the measurement can disrupt the blood pressure measurement and affect the reliability of the blood pressure readings. Consult your doctor whether the device is suitable for use in this case.\u003cbr\u003eThe device measures blood pressure using a pressure cuff. If the limbs being measured have injuries (e.g. open wounds) or are under conditions or treatments (e.g. intravenous infusion) that make it unsuitable for surface contact or pressure application, do not use the device to prevent exacerbation of the injuries or conditions.\u003cbr\u003ePatient movements during the measurement can disrupt the measurement process and affect the results.\u003cbr\u003eAvoid measuring patients with conditions, diseases, and patients prone to environmental conditions that lead to uncontrollable movements (e.g., shaking or trembling) and patients who cannot communicate clearly (e.g., children and unconscious patients).\u003cbr\u003eThe device uses an oscillometric method to determine blood pressure. The arm being measured must have normal perfusion. The device is not intended for use on a limb with restricted or impaired blood circulation. If you suffer from circulatory or blood diseases, consult your doctor before using the device.\u003cbr\u003eAvoid measurements on the arm on the side of a mastectomy or lymph node removal.\u003cbr\u003eDo not use this device in a moving vehicle (e.g., in a car or aeroplane).\u003cbr\u003e\u003cbr\u003e\u003cb\u003eComponents\u003c\/b\u003e\u003cbr\u003eBlood pressure monitor with cuff\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003eIndicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.\u003cbr\u003e\u003cbr\u003eThis device should only be used for the intended use described in this instruction manual. The manufacturer cannot be held liable for damages caused by incorrect application.\u003cbr\u003e\u003cbr\u003eDo not change the patient's medication and treatment based on the result of one or more measurements. Changes in treatment and medication should only be\u003cbr\u003eprescribed by a medical professional.\u003cbr\u003eInspect the device, cuff, and other parts for damage. DO NOT USE the device, cuff, or parts if they appear damaged or are functioning abnormally.\u003cbr\u003eProlonged interruption of blood flow reduces peripheral circulation and can cause tissue damage. Watch for signs (e.g., tissue discolouration) of obstructed peripheral circulation if performing continuous or prolonged measurements.\u003cbr\u003eProlonged exposure to cuff pressure will reduce peripheral perfusion and may lead to injury. Avoid situations of prolonged cuff pressure beyond normal measurements.\u003cbr\u003eIn the event of abnormally long pressure application, abort the measurement or loosen the cuff to reduce pressure in the cuff.\u003cbr\u003eDo not use this device in an oxygen-rich environment or near flammable gas.\u003cbr\u003eThe device is not water-resistant or waterproof. Do not spill on the device and do not immerse it in water or other liquids.\u003cbr\u003eDo not disassemble the device, accessories, and components, and do not attempt to repair it during use or storage.\u003cbr\u003eAccess to the internal hardware and software of the device is prohibited. Unauthorised access to and maintenance of the device during use or storage can compromise the safety and performance of the device.\u003cbr\u003eKeep the device away from children and individuals who cannot operate the device. Be aware of the risks of accidental swallowing of small parts and strangulation with the cables and tubes of this device and accessories.\u003cbr\u003e\u003cbr\u003eIndicates a potentially hazardous situation which, if not avoided, could result in minor or moderate injury to the user or patient, or damage to the device or other property.\u003cbr\u003eThe device is only intended for measuring blood pressure on the upper arm. Do not measure other sites, as the measurement will not accurately reflect your blood pressure.\u003cbr\u003eAfter a measurement is completed, remove the cuff and rest for \u0026gt; 5 minutes to restore limb perfusion before performing a new measurement.\u003cbr\u003eDo not use this device simultaneously with other medical electrical (ME) equipment. This may cause malfunctions in the device or inaccuracies in the measurements.\u003cbr\u003eDo not use this device near high-frequency (HF) surgical equipment, magnetic resonance imaging (MRI) equipment, and computed tomography (CT) scanners.\u003cbr\u003eThis may cause malfunctions in the device and inaccuracies in the measurements.\u003cbr\u003eUse and store the device, cuff, and components under the temperature and humidity conditions specified in the «Technical Specifications».Use and storage of the device, the cuff, and components in conditions outside the range specified in the «Technical\u003cbr\u003eSpecifications» may lead to malfunctions of the device and compromise its safe use.\u003cbr\u003eTo prevent damage to the device, protect the device and accessories from the following:\u003cbr\u003e- water, other liquids, and moisture\u003cbr\u003e- extreme temperatures\u003cbr\u003e- impact and vibrations\u003cbr\u003e- direct sunlight\u003cbr\u003e- pollution and dust\u003cbr\u003e- Stop using this device and the cuff and consult your physician if you experience skin irritation or discomfort.\u003cbr\u003e\u003cbr\u003eElectromagnetic Compatibility Information\u003cbr\u003eThis device complies with EN60601-1-2:2015 Electromagnetic\u003cbr\u003estandard electromagnetic disturbances.\u003cbr\u003e\u003cbr\u003eThis device is not certified for use near\u003cbr\u003ehigh-frequency (HF) medical equipment.\u003cbr\u003eDo not use this device near strong electromagnetic fields and portable radio frequency communication devices (e.g., microwave ovens and mobile devices). When using this device, maintain a minimum distance of 0.3 m from\u003cbr\u003esuch devices.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eStorage Advice\u003c\/b\u003e\u003cbr\u003eStorage conditions: -20 - +55 °C \/ -4 - +131 °F\u003cbr\u003e15-90 % maximum relative humidity\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOther Information\u003c\/b\u003e\u003cbr\u003eMedical device. Read the instructions for use before use.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003eMicrolife Corp., \n9F, 431, Ruiguang Road, NeiHu, \nTaipei 11492, Taiwan, China","brand":"Microlife","offers":[{"title":"1.00 Stuks","offer_id":63419702772042,"sku":"118244","price":58.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0924\/5497\/7866\/files\/4719003342821_A1N1.png?v=1788510493","url":"https:\/\/ithomepharma.com\/en\/products\/microlife-mic-bpb3-basic-bloeddrukmonitor-1-stuks","provider":"AtHomePharma","version":"1.0","type":"link"}