{"product_id":"medisana-medinose-compact-1-stuks-1","title":"Medisana Medinose compact 1 Piece","description":"\u003cb\u003eMedisana Medinose compact\u003c\/b\u003e\u003cbr\u003e\u003cbr\u003eTechnical data\n\u003cbr\u003eName and model: medisana Anti-allergy device\n\u003cbr\u003efor the nose Medinose Compact\n\u003cbr\u003e(model AN-6016)\n\u003cbr\u003ePower supply: 2 × 3V , CR2032 alkaline\n\u003cbr\u003eBattery life\n\u003cbr\u003etime:\n\u003cbr\u003eapprox. 30 treatments\n\u003cbr\u003e(3 minutes each)\n\u003cbr\u003eTechnology: phototherapy using two\n\u003cbr\u003edifferent wavelengths\n\u003cbr\u003e(652 nm and 940 nm)\n\u003cbr\u003eApplication site: nostrils\n\u003cbr\u003eClassification: internal power supply, type BF, IP22, no\n\u003cbr\u003eAP or APG, continuous operation\n\u003cbr\u003eType of light emission: continuous\n\u003cbr\u003eLight output: 3mW – 6mW\n\u003cbr\u003eOperating time: approx. 3 minutes\n\u003cbr\u003eOperating environment: temperature: 15°C – 40°C\n\u003cbr\u003ehumidity: 30% RH – 85% RH\n\u003cbr\u003eambient pressure: 80 kPa – 105 kPa\n\u003cbr\u003eStorage and\n\u003cbr\u003etransport conditions: temperature: −20°C – 60°C,\n\u003cbr\u003ehumidity: 30% RH – 85% RH\n\u003cbr\u003eambient pressure: 80 kPa – 105 kPa\n\u003cbr\u003eService life: 3 years, under normal\n\u003cbr\u003econditions of use\n\u003cbr\u003eDimensions (l × w × h): approx. 70 × 39 × 17 mm\n\u003cbr\u003eWeight: approx. 21 g\u003cbr\u003e- Effective relief of allergic rhinitis (e.g. runny nose and sneezing) \n\u003cbr\u003e- Without medication: infrared and red light therapy \n\u003cbr\u003e- Treatment time of 3 minutes \n\u003cbr\u003e- Cordless and compact design\n\u003cbr\u003e- Convenient one-button operation \n\u003cbr\u003e- With protective cover and cap \n\u003cbr\u003e- Includes batteries \n\u003cbr\u003e- Certified medical device\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWhat is this device used for\u003c\/b\u003e\u003cbr\u003eEffective relief of allergic rhinitis (e.g. runny nose and sneezing)\u003cbr\u003e\u003cbr\u003e\u003cb\u003eDirections for use\u003c\/b\u003e\u003cbr\u003eInserting the batteries\n\u003cbr\u003e• Open the battery compartment on the underside of the base unit 1.\n\u003cbr\u003e(See Fig. 9.)\n\u003cbr\u003e• Insert two CR2302 batteries. Pay attention to the polarity.\n\u003cbr\u003e(See Fig. 0.)\n\u003cbr\u003e• Close the battery compartment.\n\u003cbr\u003e\n\u003cbr\u003eNotes on the batteries\n\u003cbr\u003e• If a humming sound is heard five times in a row, the batteries are (almost) empty. Replace the old batteries with new batteries.\n\u003cbr\u003e• Remove the batteries if you do not use the device for one month (or longer). This prevents damage to the device caused by leaking batteries.\n\u003cbr\u003e• Rechargeable batteries (i.e. accumulators) are not suitable.\n\u003cbr\u003e• Do not use a new battery in combination with a used battery.\n\u003cbr\u003eDo not use batteries of different types.\n\u003cbr\u003e• Battery acid must not come into contact with your eyes. If this happens, rinse the eyes immediately with plenty of clean water and consult a doctor.\n\u003cbr\u003e• Check that the battery compartment is intact and undamaged before inserting the batteries\n\u003cbr\u003e Insert the nose probe 4 into the base unit 1.\n\u003cbr\u003e• Insert the nose piece 6 as far into the nose as is still comfortable.\n\u003cbr\u003eBy pressing on the angled adjustment 5 on both sides, the nose probe can be inserted into and removed from the nose more easily.\n\u003cbr\u003e• Press the on\/off button 2 to switch on the device. A humming sound is heard. The nose pieces 6 begin to emit red light at two wavelengths.\n\u003cbr\u003e• One therapy cycle lasts approximately three minutes. The device then automatically switches itself off. Press the on\/off button 2 if you want to switch off the device during treatment.\n\u003cbr\u003e• The Medinose Compact can be used three to five times a day with a break of five to six hours between treatments\n\u003cbr\u003e\n\u003cbr\u003eAfter finishing use \/ cleaning\n\u003cbr\u003e• Remove the batteries if you do not use the device for one month (or longer). This prevents damage to the device caused by leaking batteries.\n\u003cbr\u003e• The device is not waterproof. Therefore, do not use liquid cleaning agents that can penetrate the device. \n\u003cbr\u003e• Clean the base unit and the nose probe only with a soft, slightly damp cloth. No water may enter the device.\n\u003cbr\u003eEnsure that everything is hygienically clean afterwards.\n\u003cbr\u003e\n\u003cbr\u003e• Do not make any changes to the product that have not been approved by the manufacturer. Unauthorized changes will result in the forfeiture of any warranty claim. You may not disassemble or repair the device or its components.\n\u003cbr\u003e• Do not perform any cleaning or maintenance work while the device is switched on!\n\u003cbr\u003e• Avoid high temperatures and direct sunlight. Do not immerse the device in water, as this will damage it.\n\u003cbr\u003e• If the device has been stored at very high or very low temperatures, you must allow the device to acclimatize for approximately 2 hours first (at the temperatures indicated in Technical data, under \"Operating environment\") before using it.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eComponents\u003c\/b\u003e\u003cbr\u003eMedinose device, protective cap, batteries\u003cbr\u003e\u003cbr\u003e\u003cb\u003eWarnings\u003c\/b\u003e\u003cbr\u003eUse the device only for its intended purpose, as described in the user manual. If it is used for other purposes, the warranty will be void.\n\u003cbr\u003e\n\u003cbr\u003eThe device is not intended for commercial purposes or medical applications.\n\u003cbr\u003e• When children under 16 years of age use this product, they must be supervised by an adult.\n\u003cbr\u003e• The device is not suitable for children under 6 years of age. \n\u003cbr\u003e• Keep the device out of reach of children.\n\u003cbr\u003e• Do not look directly into the light beams, even when using an optical aid (e.g. glasses).\n\u003cbr\u003e• Do not use the device near flammable gas (e.g. anesthetic gas, oxygen or hydrogen) or a flammable liquid (e.g. alcohol). Do not use the device in an oxygen-enriched environment.\n\u003cbr\u003e• Do not use the device if you are near high-frequency devices or connected to them (e.g. for medical research).\n\u003cbr\u003e• The device may not be used near devices that emit short waves or microwaves. \n\u003cbr\u003e• Use only accessories intended for the device and supplied by the manufacturer.\n\u003cbr\u003e• You may only clean the device yourself. Do not repair the device yourself if it shows defects, as this will void any warranty claim and a safe use can no longer be guaranteed. Seek advice from your specialist retailer and have repairs carried out only by the medisana service department.\n\u003cbr\u003e• Information about possible electromagnetic interference and other interactions between the Medinose Compact and other devices, as well as information about countermeasures, can be found in 'Information on electromagnetic compatibility'. To prevent possible malfunctions caused by electromagnetic radiation emitted by other devices, we recommend keeping the Medinose Compact at a minimum distance of 30 cm from such devices (e.g. wifi routers, microwave ovens). The Medinose Compact may not be used near active medical high-frequency devices or near MRI devices\n\u003cbr\u003ebecause the electromagnetic radiation from them is exceptionally high.\n\u003cbr\u003e• The device may not be used by multiple people to avoid the transmission of infections.\n\u003cbr\u003e• Stop using immediately if you do not feel well or have pain during use and consult a doctor.\n\u003cbr\u003e• Do not drop the device, do not repair it yourself and do not make any changes.\n\u003cbr\u003e• Do not immerse the device in water or other liquids.\n\u003cbr\u003e• If the device behaves in an unexpected\n\u003cbr\u003eway during use, contact customer service.\n\u003cbr\u003e• Do not wrap the cable around your body, as this creates a risk of strangulation.\n\u003cbr\u003e• Swallowing batteries or battery acid can be extremely dangerous. Keep the device and the batteries out of reach of children and persons with disabilities. \n\u003cbr\u003e• Any type of use not described in these instructions for use may lead to a potentially dangerous emission of radiation and must therefore be avoided. \n\u003cbr\u003e• The device may not be used if you are allergic to plastic.\n\u003cbr\u003e• The device is intended to be applied by the patient themselves\u003cbr\u003e\u003cbr\u003e\u003cb\u003eStorage advice\u003c\/b\u003e\u003cbr\u003eStore at a temperature between -20 and +60°C\n\u003cbr\u003e\n\u003cbr\u003eThis device may not be disposed of with household waste. Every consumer is obliged to return all electrical or electronic equipment, whether or not it contains harmful substances, to a recycling centre or to a store where a similar product is purchased, so that it can be disposed of and processed in an environmentally friendly manner.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eOther information\u003c\/b\u003e\u003cbr\u003eWarranty and repair conditions\n\u003cbr\u003eOur warranty described below does not affect your statutory rights. For the warranty, contact your specialist retailer or the service department directly. State the defect and include a copy of the purchase receipt if the device needs to be sent back. The following warranty conditions are in\n\u003cbr\u003eeffect:\n\u003cbr\u003e1. A 3-year warranty applies to medisana products from the date of sale. In the event of a warranty claim, the date of sale must be demonstrable with a purchase receipt or invoice.\n\u003cbr\u003e2. Defects resulting from material or manufacturing faults will be rectified free of charge during the warranty period.\n\u003cbr\u003e3. The provision of a warranty does not extend the warranty period for the device or the replacement parts.\n\u003cbr\u003e4. The following are excluded from the warranty:\n\u003cbr\u003ea. all damage caused by improper use, e.g. by not following the user manual;\n\u003cbr\u003eb. damage resulting from repair or intervention by the buyer or an unauthorized third party;\n\u003cbr\u003ec. transport damage that occurred en route from the manufacturer to the consumer or during shipping to the service department;\n\u003cbr\u003ed. parts showing normal wear and tear.\n\u003cbr\u003e5. Liability for direct or indirect consequential damage caused by the device is also excluded, even if the damage to the device is acknowledged as a warranty\u003cbr\u003eMedical device. Read the user manual before use.\u003cbr\u003e\u003cbr\u003e\u003cb\u003eManufacturer \/ Distributor\u003c\/b\u003e\u003cbr\u003eMedisana GmbH, \nCarl Schurz Strasse 2, \n41460 Neuss, \nGermany","brand":"Medisana","offers":[{"title":"1 Piece","offer_id":51371652251978,"sku":"288722","price":20.82,"currency_code":"EUR","in_stock":true}],"url":"https:\/\/ithomepharma.com\/en\/products\/medisana-medinose-compact-1-stuks-1","provider":"AtHomePharma","version":"1.0","type":"link"}